LEARN · Subnetting
USABLE HOSTS
“How many hosts fit in a /27?” is probably the most-asked subnetting question there is, in exams and in change tickets. The answer is one line of arithmetic, but the real-world question is usually the reverse: you have 50 devices, so which prefix do you ask for? This guide covers both, plus the extra addresses that real networks quietly take away.
The formula
A prefix of length p leaves 32 − p host bits. The subnet holds 2(32 − p) addresses. Two of them can’t be assigned to a device: the all-zeros address names the network, and the all-ones address is the broadcast. So:
Usable hosts = 2(32 − p) − 2
That rule holds for every prefix from /1 to /30. The two exceptions are at the very end. A /31 has 2 addresses and both are usable on a point-to-point link (RFC 3021). A /32 is a single address, used for loopbacks and host routes.
The table worth knowing by heart
Most LANs, DMZs and router links use prefixes between /24 and /30. These seven rows answer most questions you’ll be asked, and the last two cover the exceptions.
| Prefix | Host bits | Addresses | Usable hosts | Typical use |
|---|---|---|---|---|
| /24 | 8 | 256 | 254 | Standard LAN or VLAN |
| /25 | 7 | 128 | 126 | Half a /24: split user VLANs |
| /26 | 6 | 64 | 62 | Small office, printer or voice VLAN |
| /27 | 5 | 32 | 30 | Server or management segment |
| /28 | 4 | 16 | 14 | Small DMZ, ISP public block |
| /29 | 3 | 8 | 6 | Firewall pair, small public block |
| /30 | 2 | 4 | 2 | Point-to-point router link |
| /31 | 1 | 2 | 2 | Point-to-point link (RFC 3021) |
| /32 | 0 | 1 | 1 | Loopback or host route |
The pattern is simple: every extra prefix bit halves the subnet. If you remember that a /24 has 256 addresses, you can rebuild the rest of the table in a few seconds.
Sizing a subnet for a number of devices
To choose a prefix, find the smallest subnet whose usable count covers what you need:
- Count the devices that need an address, including the gateway.
- Add headroom. Subnets are painful to resize later, so plan for growth, often 25 to 50% for user VLANs.
- Pick the first prefix in the table whose usable hosts are at least that number.
Some worked answers:
- 12 hosts: a /28 gives 14. That’s tight; a /27 (30) is the safer choice if more might arrive.
- 50 hosts: a /27 gives only 30, so you need a /26 (62).
- 100 hosts: a /25 (126).
- 200 hosts: a /24 (254).
- 500 hosts: a /24 isn’t enough, so step up to a /23 (510).
- 2 hosts on a router link: a /30, or a /31 if both ends support it.
Note that 254 hosts fit exactly in a /24, but “exactly” means no spare addresses at all. In practice you would almost never plan a subnet to be 100% full on day one.
The addresses you don’t get
The formula gives the theoretical number. Real networks take a few more away before your first device gets an address.
Gateways and redundancy. The default gateway uses one address. With a first-hop redundancy protocol such as HSRP or VRRP, a router pair typically uses three: one for each router and one virtual address that hosts point to. A /29 has 6 usable addresses, so after a redundant gateway it has room for only 3 devices.
Cloud providers. AWS and Azure each reserve five addresses in every subnet. In AWS these are the network address, the VPC router (+1), the DNS server (+2), one reserved for future use (+3) and the broadcast address. Azure reserves the same count for similar purposes. So a /28 cloud subnet gives 11 usable addresses rather than 14, and a /24 gives 251 rather than 254. AWS subnets can’t be smaller than a /28. Azure’s smallest is a /29, which leaves only 3 usable addresses.
DHCP scopes and static ranges. A subnet’s usable count isn’t the same as its DHCP pool. If you reserve the first 20 addresses for switches, printers and access points, a /24 offers 234 addresses to clients, not 254.
Common mistakes
- Counting addresses instead of usable hosts. A /26 has 64 addresses but holds 62 devices.
- Choosing by the address count. 64 devices don’t fit in a /26: they need a /25.
- Forgetting the gateway. It’s an address on the subnet like any other device.
- Copying on-premises sizes into the cloud. Five reserved addresses can turn a “just big enough” /28 into one that’s too small.
Practice
The host-count field in Subnetle is scored separately, and its feedback tells you when you’re within a factor of two. That makes it a quick way to check whether you’ve really got the halving pattern down.
Practice it: Subnetle puts this into a daily game, free in your browser.
FAQ
How many usable hosts are in a /27?
30. A /27 has 5 host bits, so 2 to the power of 5 is 32 addresses, minus the network and broadcast addresses.
What prefix do I need for 50 hosts?
A /26, which has 62 usable addresses. A /27 only has 30. Pick the smallest subnet whose usable count is at least the number of devices, plus room to grow.
Why does my cloud subnet have fewer addresses than the formula says?
AWS and Azure both reserve five addresses in every subnet: the network address, the broadcast address and three more for the virtual router, DNS and future use. A /28 in either cloud gives 11 usable addresses, not 14.
Should I use /30 or /31 for router links?
If both devices support RFC 3021, a /31 uses half the addresses for the same link. A /30 still works everywhere and is the safe default on older equipment.
SOURCES
- RFC 3021: Using 31-Bit Prefixes on IPv4 Point-to-Point Links
- AWS: Subnet CIDR blocks (reserved addresses)